Unarmed thrust reverser received a deploy command.
Aircraft in takeoff configuration, dynamic test OK.
The respective APR circuit has passed the self-test.
Fuel shutoff valve is closed after activation of the respective ENG FIRE PUSH

switch/light.
’A’ igniters are activated, ’B’ igniters off.
Both ’A’ and B’ igniters are activated.
’B’ igniters are activated, ’A’ igniters off.
The respective thrust reverser is armed.

The respective DCU has failed its APR test.

The respective engine ECU failed to respond to an APR test.