Each engine may be replenished individually if:
.  
The engine has been shut down for a minimum of 15 minutes and to a maximun of 30 minutes.

.  
The engine to be replenished is not already full.

.  
The aircraft has Weight on Wheels (WOW).

.  
One of the other engines or APU is not currently being replenished.


Rev 2A, Apr 11, 2005 Flight Crew Operating Manual  Volume 2

POWER PLANT
 
Oil Replenishment Panel
LO OIL LH ENG (right engine similar)
The LO OIL comes on to indicate that the engine is low in oil quantity and will remain on until the engine oil tank is replenished.

TANK LO
The reservoir TANK LO legend comes on to indicate that the reservoir is low in quantity.

PUMP ON
Selecting the PUMP ON switch does the
following:


 The reservoir pump will operate and the PUMP ON lamp will come on to indicate operation. The legend will remain on until the correct level of the system to be topped up is achieved.


SYSTEM ON
Selecting the POWER switch to ON does the following:
The SYSTEM ON lamp will come on.
 A three second lamp test will be carried out on all annunciators.
Provides power to all switches on the oil replenishment panel.
VLV OPEN RH (left engine similar)
Selecting the switch will illuminate the VLV OPEN switch legend indicating valve operation. Oil will be pumped from the reservoir (through the valve) to the engine until full is achieved.

 The VLV OPEN and LO OIL switch legends will go out when the correct level is reached.
GF1810_013
Oil is to be added to the engine(s) when an OIL LO QTY message is displayed on EICAS and when

is displayed on the oil replenishment panel with the replenishment system
powered.
Volume 2 Flight Crew Operating Manual Rev 2A, Apr 11, 2005
POWER PLANT
 
Oil Replenishment Schematic
AIRFRAME-MOUNTED 
OIL REPLENISHMENT POWER 
AIRFRAME-MOUNTED  SYSTEM ON 
O  RESERVOIR TANK LO PUMP ON  LH ENG LO OIL VLV OPEN  APU LO OIL VLV OPEN  RH ENG LO OIL VLV OPEN 

GF1810_015
Operation
The following procedural steps outlined are to be used only as a guide to replenish the engine oil system. The Airplane Maintenance Manual takes precedence over all servicing procedures.
.  
Select the “POWER”switch on the oil replenishment panel, “SYSTEM ON”legend on.

.  
Confirm that the “LO OIL”lamp on the oil replenishment panel corresponds to the condition indicated on EICAS “L (R) OIL LO QTY”caution message (if message present).

.  
Select the switch labeled “LH or RH ENG”on the oil replenishment panel.

.  
Confirm that the “PUMP ON”(below reservoir label) and “VLV OPEN”(below the engine to be filled) legends are displayed on the oil replenishment panel.
 