OVERWATER EMERGENCY EQUIPMENT
LIFE VEST
Life vests are provided for crew and passengers. Flight crew life vests are located under the pilot and copilot’s seats. The passenger life vests are located in a compartment under each passenger seat. The life vests are inflated by pulling the red CO2 release tabs. An oral inflation tube is also available if the CO2 cartridge does not inflate the vest.

CFO0801002_007
Sep 13/2004 Flight Crew Operating Manual Volume 2 REV 1 CSP 100-6
08-01-17
To don the life vest, proceed as follows:
1. FIND THE LIFE VEST UNDER 2. PUT THE LIFE VEST OVER 3. ...WITH THE BACK PIECE THE SEAT. HEAD... BEHIND.
4. FASTEN RINGS TO CATCH  5. PULL STRAPS TIGHT 6. JERK DOWN ON INFLATION TABS. INFLATE LIFE VEST JUST BEFORE JUMPING OUT OF THE AIRPLANE! USING OVERWING EMERGENCY EXIT INFLATE
LIFE VEST WHEN ON THE WING.
NOTE
7. SHOULD IT BECOME NECESSARY, When using adult/child life vest for children,
LIFE VEST CAN BE ORALLY pass the straps between legs, fasten hooks.
INFLATED BY BLOWING INTO ORAL Inflate only one chamber.
INFLATION TUBES.

CFO0801002_008
Volume 2 Flight Crew Operating Manual Sep 13/2004 CSP 100-6 REV 1
08-01-18
LIFE RAFTS (OPTIONAL)
Two optional self contained 4 person life rafts are provided for passengers and crew. They are located either on the bottom shelf of the galley, crew closet, or in the aft pyramid cabinet, depending on cabin configuration. Refer to Air Cruisers Com-pany Operator’s Guide for further information.
(DOORS REMOVED FOR CLARITY) (DOOR REMOVED FOR CLARITY) (DOOR REMOVED FOR CLARITY)
DELUXE GALLEY PYRAMID CABINET CREW CLOSET
CONTROLS AND INDICATIONS PASSENGER OXYGEN CONTROL PANEL
THERAPEUTIC  OXYGEN  PAX AUTO 
OFF  DEPLOY 
ON 

PLACARDS
O2
HALON FIRE OXYGEN
EXTINGUISHER CYLINDER

CFO0801002_004
CFO0801002_001
CREW MEMBER
LIFE-VEST UNDER
SEAT

FIRST AID KIT
Sep 13/2004 Flight Crew Operating Manual Volume 2 REV 1 CSP 100-6
08-01-19 EICAS MESSAGES
The oxygen system messages are shown on the EICAS. Oxygen system messages and inhibits are listed below. A brief explanation of each message is provided.
MESSAGE  INHIBITS  MEANING  AURAL WARNING 
OXYGEN QUANTITY LOW  TO/LAND  Oxygen is less than 700 liters 
OXYGEN VALVE CLOSED  TO/LAND  The oxygen bottle valve is closed or there is a miscompare in the number of bottles installed and the number of bottles selected on the Elec-tro-Pneumatic Actuating Valve unit. This mes-sage will normally only occur on the ground 
PAX OXYGEN AUTO FAIL  TO/LAND  Passenger oxygen system has failed to deploy with the cabin altitude greater than 15 000 ft and the pax oxygen system in AUTO. Either the pax masks have not deployed or the pax oxygen sys-tem is not pressurized 
 