BLEED OFF  The L, R, and APU BLEEDs are OFF 
DITCHING ON  The DITCHING switch/indicator has been selected ON. This closes the flow control valves and commands the outflow valve open for 100 seconds or 10 seconds after cabin differential pressure decreases below 1595 psid. The outflow valve then closes 
EMER DEPRESS ON  Emergency depressurization has been selected. Emergency depressurization commands the out-flow valve open, but will attempt to limit the cabin altitude to approximately 15 000 ft 
MANUAL PRESS ON  The MANUAL PRESSURIZATION mode has been selected 
PACK ONLY  The AIR SOURCE switch is in the PACK ONLY position, resulting in all air conditioning bleed air being routed through the PACK 
RAM AIR ON  The RAM AIR switch has been selected ON, providing ram air ventilation 
XBLEED OPEN  The cross bleed valve is open 
TRIM AIR ONLY  The AIR SOURCE switch is in the TRIM AIR ONLY position, resulting in all air conditioning bleed air being routed through the trim air sys-tem. The air will be warm 

Volume 2 Flight Crew Operating Manual Sep 13/2004 CSP 100-6 REV 1
02-04-12
 


 