返回首页

庞巴迪环球5000公务机机组操作手册 Bombardier Global-空调和增压(8)

时间:2011-11-03 11:52来源:蓝天飞行翻译 作者:公务机
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
  
 TEMPERATURE CONTROL VALVE (TCV)
COMPRESSOR PNEUMATIC OVERHEAT SENSOR

COMPRESSOR DISCHARGE TEMPERATURE SENSOR AFT PRESSURE BULKHEAD

PACK DISCHARGE TEMPERATURE
SENSOR (PDTS)  PACK TEMPERATURE  RAM AIR VALVE 

 SENSOR (PTS) 
 
WATER EXTRACTOR  PTS  WATER EXTRACTION 

 LOOP 

 RE 

HEATERCONDENSER
RAM
AIR INLET

CPNOH  CPNOH
CDTS CDTS
WATER
SPRAYER

PRIMARY HEAT DUAL HEAT
EXCHANGEREXCHANGER

PLENUM CHECK VALVE
FLOW CONTROL
VALVE (FCV)

FCV
BLEEDBLEED
 AIR AIR

PDPS

PDTS
ACM
TCV

 


GF0210_019
Volume 2  Flight Crew Operating Manual Rev 2A, Apr 11, 2005

Cooling Packs (Cont’d)
The cooling packs are shutoff (FCV closed) under the following circumstances:
.  
In AUTO operation, by the ACSC acting on the FCV torque motor due to:

.  
Bleed failure or shutdown (on BMC demand).

.  
Engine starting (on BMC demand).

.  
During ditching operation, if airplane is below 15,000 feet.

.  
Pack inlet overheat.

.  
Compressor discharge overheat.

.  
Pack discharge overheat.

.  
Pack discharge underpressure.

 


Full closed position to ACSC
Torque motor control from ACSC
FCV


GF0210_020
.  In AUTO or MANUAL operation, by the compressor pneumatic overheat sensor (CPNOH), acting pneumatically on the FCV actuator due to compressor discharge overheat or by crew selection of the PACK switch, acting on the FCV solenoid.

 

 


FCV ON/OFF solenoid command from L or R PACK switch
GF0210_021
Rev 2A, Apr 11, 2005 Flight Crew Operating Manual  Volume 2

AIR CONDITIONING AND PRESSURIZATION
 
Flow Control System
The flow control system regulates airflow from the pneumatic duct to the air conditioning units.
The flow control system interfaces with:
.  
Bleed Air System . The flow control system takes bleed air from the engine, the APU, or a ground source and provides filtered air into the air conditioning units.

.  
Air Conditioning System Controllers (ACSC) which measure, calculate and control the airflow.

.  
Air Conditioning Units (packs) which use the filtered air supply.


A flow control valve (FCV) will modulate to meet a preset flow schedule and is normally controlled by the Air Conditioning System Controller (ACSC).
When an overheat is detected, the ACSC will automatically close the FCV and display the affected caution message on EICAS.

 


FCV
to ACSC
 
中国公务机网 www.gongwuji.com
公务机翻译 www.aviation.cn
本文链接地址:庞巴迪环球5000公务机机组操作手册 Bombardier Global-空调和增压(8)
 

------分隔线----------------------------