BUS KEY (CONT'D) 
AV BATT BUS 


CB . AV BATT BUS AREA LTS AV BATT CHGR LD AV BATT MSTR AV BATT RCCB CLOCK BACKUP APU FADEC PWR 2 DCPC DCPC DCPC DCPC CCBP DCPC  1/2 IN IN IN IN IN IN 
CB . AV BATT BUS  2/2 
EMS CDU 1 PWR A FWD MAINT LTS PAX DOOR MOTOR DC EMER FEED 1 DCPC DCPC DCPC DCPC DCPCSTAIR LTS CCBPSTBY ADI  IN IN IN IN IN IN 

GF0720_111
Rev 2A, Apr 11, 2005 Flight Crew Operating Manual Volume 2

 ELECTRICAL 
EMS CIRCUIT PROTECTION 
BUS KEY (CONT'D) 
APU BATT BUS 


CB . APU BATT BUS AFT MAINT LTS APU BATT CHGR LD APU BATT MSTR APU BATT RCCB APU DOOR ACPC CTL PWR D ASCA ASCA ASCA CCBP ASCA ASCA  1/3 IN IN IN IN IN IN 

CB . APU BATT BUS FUEL R/D CH B CTR 2 INTG LTS B EMS CDU 2 PWR A FUEL R/D CH A R/D MOTOR VALVES APU START CONTACT ASCA ASCA ASCA ASCA ASCA ASCA  2/3 IN IN IN IN IN IN 
CB . APU BATT BUS  3/3 
R/D PANEL COCKPIT R/D PANEL EXT R/D SOL VALVES ASCA ASCA ASCA  IN IN IN 

GF0720_113
Volume 2 Flight Crew Operating Manual Rev 3, Apr 25, 2005

ELECTRICAL EMS CIRCUIT PROTECTION
CNTL KEY
CNTL Key is used to display system control options.

HUMIDIFIER SWITCH CONTROL STALL WARN ADVANCE LEFT FOOTWARMER RIGHT FOOTWARMER SLAT/FLAP RESET  1/3 OFF NORM ON ON ON 

SWITCH CONTROL AC 2 CABIN PWR AC 3 CABIN PWR AC 4 CABIN PWR AC 1 CABIN PWR SWITCH CONTROL DC 1 CABIN PWR  2/3 ON ON ON ON 3/3 ON 

DC 2 CABIN PWR 1 DC 2 CABIN PWR 2 DC 2 CABIN PWR 3 DC 2 CABIN PWR 4  ON ON ON ON 
NOTE 

STALL WARN ADVANCE is either NORM or ADVANCE, see Chapter 10 for more information.
GF0720_114
Rev 3, Apr 25, 2005 Flight Crew Operating Manual Volume 2

ELECTRICAL
 
EMS CIRCUIT PROTECTION
 
TEST KEY
TEST Key is used to display and initiate test options. When TEST key is selected FIRE TEST is automatically highlighted. The TEST function can only be initiated by selecting the associated key. After a TEST is complete, the next selection will automatically be highlighted. To terminate a TEST, re-select appropriate key.

FGF0720_001
NOTE
When a test has been initiated via the EMS-CDU and the test is either manually or automatically terminated, there is a 2 second delay before the test sequences to the next test. Do not attempt to force the termination of a test by trying to select another test. Allow for the EMS-CDU to cycle to the next test before selecting the desired test.
Volume 2 Flight Crew Operating Manual Rev 3, Apr 25, 2005

ELECTRICAL
 
EMS CIRCUIT PROTECTION
 
TEST KEY (CONT'D)
 
FIRE TEST


FIRE TEST:
(duration approximately 10 seconds) Press the FIRE TEST activation button and note the following:

Fire and smoke aural warnings are activated.
 