FIRE PROTECTION
 
TABLE OF CONTENTS
 
CHAPTER 9 
Page 
TABLE OF CONTENTS  09.00.1 
DESCRIPTION 
General  09.10.1 
Flight Compartment Fire Warning  09.10.2 
Fire Detecting System  09.10.2 
Wheel Well Overheat Warning  09.10.2 
Fire Agent Discharge Indication  09.10.2 
Smoke Detection  09.10.2 
Portable Fire Extinguishers  09.10.2 
System Overview Schematic  09.10.3 
Fire Control Handles  09.10.4 
Engine Fire Control Handle  09.10.5 
APU Fire Control Handle  09.10.5 
Synoptic Pages  09.10.6 
Fire Extinguisher assembly  09.10.7 
Fire Extinguisher Discharge Squibs  09.10.7 
Fire Extinguisher Gauges  09.10.8 
Fire Zone Discharge Schematic  09.10.8 
FIDEEX Control Unit  09.10.9 
Main Engine Fire Detection  09.10.10 
Main Engine FIDEEX Control  09.10.12 
Engine FIDEEX Control Schematic  09.10.13 
APU Compartment Fire Detection  09.10.14 
APU FIDEEX Control Schematic  09.10.15 
APU FIDEEX/FADEC Interface  09.10.16 
APU FIDEEX/FADEC Control Schematic  09.10.16 
Main Wheel Well (MWW) Overheat Detection  09.10.17 
Smoke Detection  09.10.18 
Pilot Initiated Test  09.10.20 
EICAS Messages  09.10.22 
EMS CIRCUIT PROTECTION 
CB . Fire System  09.20.1 

Rev 2A, Apr 11, 2005 Flight Crew Operating Manual Volume 2


FIRE PROTECTION
 
TABLE OF CONTENTS
 

THIS PAGE INTENTIONALLY LEFT BLANK

Volume 2 Flight Crew Operating Manual Rev 2A, Apr 11, 2005

GENERAL
A Fire Detection and Extinguishing (FIDEEX) system with fault discrimination is installed with fire detectors located in each engine nacelle and in the APU compartment.
The FIDEEX system interfaces with numerous airplane equipment and provides the following capabilities:
.  
Monitor zones for fire/overheat/smoke events and FIDEEX system health and status.

.  
Automatic detection and reporting of fire events for each of the two power plants and the Auxiliary Power Unit (APU).

.  
Fire extinguishing for each of the power plant and APU upon receipt of pilot initiated arming and discharging commands.

.  
Automatic detection and reporting of overheat events for the two Main Wheel Wells (MWWs).

.  
Automatic detection and reporting of smoke events for each of the lavatories (fwd/aft), baggage compartment, up to four cabin closets (requires installation of optional smoke detectors) and avionics bay.
 