曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
FIRE PROTECTION
TABLE OF CONTENTS
CHAPTER 9
Page
TABLE OF CONTENTS 09.00.1
DESCRIPTION
General 09.10.1
Flight Compartment Fire Warning 09.10.2
Fire Detecting System 09.10.2
Wheel Well Overheat Warning 09.10.2
Fire Agent Discharge Indication 09.10.2
Smoke Detection 09.10.2
Portable Fire Extinguishers 09.10.2
System Overview Schematic 09.10.3
Fire Control Handles 09.10.4
Engine Fire Control Handle 09.10.5
APU Fire Control Handle 09.10.5
Synoptic Pages 09.10.6
Fire Extinguisher assembly 09.10.7
Fire Extinguisher Discharge Squibs 09.10.7
Fire Extinguisher Gauges 09.10.8
Fire Zone Discharge Schematic 09.10.8
FIDEEX Control Unit 09.10.9
Main Engine Fire Detection 09.10.10
Main Engine FIDEEX Control 09.10.12
Engine FIDEEX Control Schematic 09.10.13
APU Compartment Fire Detection 09.10.14
APU FIDEEX Control Schematic 09.10.15
APU FIDEEX/FADEC Interface 09.10.16
APU FIDEEX/FADEC Control Schematic 09.10.16
Main Wheel Well (MWW) Overheat Detection 09.10.17
Smoke Detection 09.10.18
Pilot Initiated Test 09.10.20
EICAS Messages 09.10.22
EMS CIRCUIT PROTECTION
CB . Fire System 09.20.1
Rev 2A, Apr 11, 2005 Flight Crew Operating Manual Volume 2
FIRE PROTECTION
TABLE OF CONTENTS
THIS PAGE INTENTIONALLY LEFT BLANK
Volume 2 Flight Crew Operating Manual Rev 2A, Apr 11, 2005
GENERAL
A Fire Detection and Extinguishing (FIDEEX) system with fault discrimination is installed with fire detectors located in each engine nacelle and in the APU compartment.
The FIDEEX system interfaces with numerous airplane equipment and provides the following capabilities:
.
Monitor zones for fire/overheat/smoke events and FIDEEX system health and status.
.
Automatic detection and reporting of fire events for each of the two power plants and the Auxiliary Power Unit (APU).
.
Fire extinguishing for each of the power plant and APU upon receipt of pilot initiated arming and discharging commands.
.
Automatic detection and reporting of overheat events for the two Main Wheel Wells (MWWs).
.
Automatic detection and reporting of smoke events for each of the lavatories (fwd/aft), baggage compartment, up to four cabin closets (requires installation of optional smoke detectors) and avionics bay.