DASSAULT FALCON 900EX EASY SYSTEMS SUMMARY Air Conditioning & Pressurization(15)

时间:2012-01-12 15:51来源:蓝天飞行翻译 作者:公务机

To view this page ensure that Adobe Flash Player version 9.0.124 or greater is installed.

曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者
  
-activate mode selection of NORMAL or FLIGHT LEVEL laws,
-enter and override the destination landing field elevation through the LDG ELEV box,
-activate the selection of LOW Cabin Rate.

 


Synthetic table

CONTROL  FUNCTION  TO ACTIVATE  SYNOPTIC 
TO DEACTIVATE 
status light  -Allows the selection of automatic / MAN mode of the pressurization system -In MAN mode, use the manual pressurization control knob  Push on: MAN mode Push off: automatic 
 
pushbutton  mode 
status light guarded pushbutton  -Closes the CABIN conditioning valve and drives the CKPT temperature control valve to the fully hot position  Raise the guard and push on: EMERG mode  Air conditioning synoptic 
status light  Raise the guard and 
push on: 
DUMP 
-Allows a rapid  mode 
depressurization by 
forcing the outflow 
valves to fully open 
Guarded: 
guarded pushbutton  automatic mode 

 


INDICATION ECS synoptic

ECS SYNOPTIC IN AUTOMATIC MODE

ECS SYNOPTIC IN MAN MODE CABIN DIFFERENTIAL PRESSURE INDICATIONS

 

 

CABIN ALTIMETER INDICATIONS

 

 

 CABIN VARIOMETER INDICATIONS
STAT synoptic

 STAT SYNOPTIC

 

SYSTEM PROTECTION

 

CIRCUIT BREAKERS

The electrical circuit protection is provided by conventional trip-free circuit breakers located above the overhead panel (refer to Air conditioning).

PRESSURIZATION SYSTEM PROTECTION
Pressurization system protection consists of maximum differential pressure limitation, negative differential pressure prevention and cabin altitude limitation. Each outflow valve performs all protections.
Maximum differential pressure limitation
 