Synoptic pages are available as a page overlay, and are normally viewed on the lower window of a MFD. Each EICAS synoptic page allows the crew to view a dynamic representation of the:
.  
AC electrical system;

.  
DC electrical system;

.  
Hydraulic system; and

.  
Flight control system.


Synoptic pages are selectable on the lower window of the MFD by buttons on the cursor control panels (CCP). The buttons are labelled according to the system being represented: AC ELEC, DC ELEC, HYD, FLT.


 AURAL/VISUAL WARNING SYSTEM Description  Vol. 2  03.10.12 
Oct 05/06 

Synoptic pages can also be shown on the upper window of an MFD that is not configured as an EICAS page. This feature can only be selected from the upper window main menu of the MFD, which is not available when the EICAS page is locked on the MFD. Locking the EICAS page on a particular MFD is a function of the EICAS selector on the reversionary control panel.
The synoptic pages include digital readouts, colored flow lines, component outlines and system messages. Specific colors are used to depict normal, precautionary and maximum system limits as follows:
.
Indicator is green; normal range;

.
Indicator turns amber; precautionary range; and

.
Indicator turns red; limits exceeded.


Specific colors are used to depict the flow lines as follows:
.
Black, indicates no flow;

.
Amber, indicates below normal values;

.
Green, indicates normal value; and

.
Red, indicates exceeding normal values.


When a synoptic page is being shown, a tab, located in the right corner of the synoptic page, identifies which navigation format is being displayed. Selection of the quick access button for the synoptic page being displayed causes the page to be removed and replaced with the previously selected format (as identified by the tab).


 AURAL/VISUAL WARNING SYSTEM Description  Vol. 2  03.10.13 
Oct 05/06 


Synoptic Page Selection (1 of 3)
Figure 03.10.11

 

 AURAL/VISUAL WARNING SYSTEM Description  Vol. 2  03.10.14 
Oct 05/06 


Synoptic Pages (2 of 3)
Figure 03.10.12

 

 AURAL/VISUAL WARNING SYSTEM Description  Vol. 2  03.10.15 
Oct 05/06 


Synoptic Pages (3 of 3) Figure 03.10.13

EICAS SUMMARY Page
The EICAS SUMMARY page is selectable by the SUMRY button on the CCP. The SUMMARY page is presented as an overlay on the lower window of the MFD. If required, the SUMMARY page can also be shown on the upper window of the MFD not currently configured to show the EICAS page. This function can be selected from the upper window menu when enabled.
 