APU FIRE EXT B  R6 
CargoSmokeCargo Smoke Detection  CARGO FIREX 1  DC BATT BUS  P1 
CARGO FIREX 2  DC BUS 1  G1 

Flight Crew Operating Manual  MASTER 
CSP A-
013 


 FIRE PROTECTION Fire Detection and Extinguishing (FIDEEX)  Vol. 1  10-
20-
24 
REV 56, Jan 31/03 

THISPAGEINTENTIONALLYLEFTBLANK

Flight Crew Operating Manual  MASTER 
CSP A-
013 


 FIRE PROTECTION  Vol. 1  10-
30-

Lavatory  REV 56, Jan 31/03 

 

1. LAVATORY FIRE PROTECTION
Lavatoryfiredetection andprotection consists of a ceiling mounted smoke detectorand a waste compartmentfire extinguisher.
A. Detection
The smoke detectormonitors thelavatoryforthepresence of smoke. Whenthe smoke density exceeds apresetlevel, thedetectorsounds anauralalarm andaSMOKE TOILET caution messageis displayed on theEICASprimarypage.
The smoke detector monitors thelavatoryforthepresence of smoke. Whenthe smoke density exceeds apresetlevel, thedetectorsounds anauralalarm andaSMOKE TOILET warning messageis displayed on theEICASprimarypage. <0037>
The smoke detectorcan betestedbypressingthetestbutton on thedetector. During thetest, anauralalarm soundsin thelavatory, theredalarm light onthedetector comes on andaSMOKETOILET caution messageis displayed on the EICASprimary page. The systemis resetbypressingtheinterruptbutton on thedetector.
The smoke detectorcan betestedbypressingthetestbutton on thedetector. During thetest, anauralalarm soundsin thelavatory, theredalarm light onthedetector comes on and aSMOKETOILET warning message isdisplayed on the EICASprimary page. The systemis resetbypressingtheinterruptbutton on thedetector. <0037>
NOTE
Operationofmobiletransceiversincloseproximityto the smoke detectors or exhaust fumes from ground equipment may cause afalse alarm.
Flight Crew Operating Manual  MASTER 
CSP A-
013 

Vol. 1
10-
30-
2
FIRE PROTECTION
REV56,Jan 31/03
Lavatory
Alarm Light (red) Comes on with the  Power Light (green) Comes ontoindicate  Interrupt Pushbutton 
aural alarm to indicate  that the unit is powered.  Used to reset smoke detector. 
that a smoke condition 
exists in the lavatory.  Test Pushbutton 
Used to test smoke detector. 
When pressed in: 
Aural alarm comes on. 
Alarm light comes on. 
EICAS warning message 
is displayed. 

Smoke Detector Lavatory Ceiling
SMOKETOILET
<0039> <0006>
700and2000Hz tone
SMOKE TOILET Caution (amber)
Comes on withthe auralalarm to indicate that asmoke condition exists inthe lavatory.
 