 FIRE PROTECTION  Vol. 1  10-
20-
13 

Fire Detection and Extinguishing (FIDEEX)  REV 56, Jan 31/03 

APU FIRE PUSH
Usedto arm theAPUbottle squib. Closes theAPUbleedair load control valve andturns off theAPUfuelpump.

APUFIREPUSH(red)light
indicates that afire is detected
intheAPU enclosure.

 

 


BOTTLE ARMED PUSH TO DISCH
Usedto dischargetheAPUbottle.

BOTTLEARMEDPUSHTO DISCH (green) light indicates that the bottle squibis armedandthe bottles is charged.
Fire Detection and Extinguishing ---APU PushButtons
Figure 10---20---7

Flight Crew Operating Manual  MASTER 
CSP A-
013 


 FIRE PROTECTION Fire Detection and Extinguishing (FIDEEX)  Vol. 1  10-
20-
14 
REV 56, Jan 31/03 


APUFire ExtinguishingSystem
Figure 10--20--8

Flight Crew Operating Manual  MASTER 
CSP A-
013 


 FIRE PROTECTION  Vol. 1  10-
20-
15 

Fire Detection and Extinguishing (FIDEEX)  REV 56, Jan 31/03 

<0039>


APU SQUIB 1, 2 Advisory message (green)
Comes on to indicate that the respective element on the squib is operative.

APU FIRE Warning (red)
Comes ontoindicate that a fire exists in the

APU FIRE FAIL Caution (amber)
Comes on to indicate that a failure exists in the APU fire sensing loops

APU BTL LO Caution (amber)
Comes on to indicate that the APU
firex bottle discharged.

 

--Firebell -
Exterior Horn (Sounds on ground and system will automatically discharge after 5 seconds).
<0039>

<0039>

Flight Crew Operating Manual  MASTER 
CSP A-
013 


 FIRE PROTECTION Fire Detection and Extinguishing (FIDEEX)  Vol. 1  10-
20-
16 
REV 56, Jan 31/03 

APU FIRE EXTINGUISHING 
EVENT  RESULT  GLARESHIELD INDICATIONS 
APU FIRE PUSH  BOTTLE ARMED PUSH TO DISCH  MASTER WARN-ING 
1  Fire condition occurs in APU fire zone.  -
Firebell sounds. -
MASTER WARNING and APU FIRE PUSH lights come on. -
APU shuts down automatically. If the aircraft is on the ground: -
The APU bottle automatically discharges after 5 seconds.  ON  OUT  ON 
2  MASTER WARNING is pressed in.  -
Firebell is silenced. -
MASTER WARNING light goes out and system is reset.  ON  OUT  OUT 
3  APU FIRE PUSH switchlight is pressed in.  -
BOTTLE ARMED PUSH TO DISCH light comes on. -
If airborne, the APU fire shutoff relay is energized to shut down the APU. -
APU squibs are armed. -
 