Whenthe controlunitdetects afailure in oneloop,dueto ashort orpower loss, there is no indication ofthe failure untilthe WARNtestis performed. The control unitwill automatically switchto single loopdetection. Single loopoperation can also be selectedbyplacingthedefective loop switch ontheFIREDETECTIONpanelfrom BOTHtothegoodloop(A orB). During normaloperations with oneloop selected,the followingtable liststheindications thatare displayed if a fire,failure, or power loss is detected:
LOOP CONDITION (Dual Loops)  INDICATIONS 
LOOP A  LOOP B  FAIL MESSAGE (Caution)  FIRE WARNINGS 
Normal  Normal 
Detecting Fire  Detecting Fire  ON 
Short orPower Failure  Short orPower Failure  ON 
Normal  Detecting False Fire  ON 
Normal  Short orPower Failure 
Detecting Fire  Short orPower Failure  ON 
Detecting False Fire  Normal  ON 
Open  Normal 
Short orPower Failure  Open 
Open  Open 
Open detecting fire  Detecting Fire  ON 
NOTE: 1. Normal, means a serviceable loop with no fire or short detected. 2. False Fire, means one loop detects a fire and the other loop is normal. 3. When a jet pipe overheat is detected, the ENG FIRE switchlight does not illuminate with the EICAS and aural warnings. 

Flight Crew Operating Manual  MASTER 
CSP A-
013 


 FIRE PROTECTION Fire Detection and Extinguishing (FIDEEX)  Vol. 1  10-
20-

REV 56, Jan 31/03 

LOOP CONDITION (single loop)  INDICATIONS 
LOOP A or LOOP B  FAIL MESSAGE  FIRE WARNINGS 
Normal 
Detecting Fire  ON 
Short orPower Failure  ON 
Open 
Open with fire  ON 


C. Testing
The controlunitprovides ameans oftestingthedetection systembyselectively simulatingfire/overheatandfail conditions ontheselectedloops(A orB). Thefollowing table liststhepossible loop conditions whentheWARNtestis performed:
LOOP CONDITION (Both Loops selected)  INDICATIONS 
LOOP A  LOOP B  FAIL MESSAGE (Caution)  FIRE WARNINGS 
Normal  Normal  ON 
Open loop  Open loop 
Short orPower Failure  Short orPower Failure  ON 
Normal  Open loop 
Normal  Short orPower Failure  ON  ON 
Short orPower Failure  Open loop  ON 
Open loop  Normal 
Short orPower Failure  Normal  ON  ON 
Open loop  Short orPower Failure  ON 

Flight Crew Operating Manual  MASTER 
CSP A-
013 


 FIRE PROTECTION  Vol. 1  10-
 