The startermotoris deactivated at50% rpm andtheSTARTlegendgoesout. When theAPUreaches99% rpm, ignition is turnedoffandtwo secondslatertheAVAIL legend,in the START/STOP switchlight,illuminates to notifythe crew thatthe APUis readyto supply electricalpower andbleedair.
(1) APUStarterLimits
SOURCE  START # and TIME ON  COOLING TIME 
1 30 seconds  No cooling required 
BatteryBattery  2 30 seconds  20 minutes 
3 30 seconds  No cooling required 
4 30 seconds  40 minutes 
1 15 seconds  No cooling required 
x erna owerE
xt
ernal
D
C
P
ower  2 15 seconds  20 minutes 
3 15 seconds  No cooling required 
4 15 seconds  40 minutes 

Flight Crew Operating Manual  MASTER 
CSP A-
013 


 AUXILIARY POWER UNIT Control  Vol. 1  04-
40-

REV 56, Jan 31/03 


NOTE

Itisrecommendedthata2minutedelaybeobserved betweenstartattemptstoallowforcoolingoftheAPU start contactorandforfueldrainage.
Effectivity:
W Airplanes7003to7100notincorporatingServiceBulletin601R-
28-
008
NOTE

During normal operations, a nuisance XFLOW/APU PUMPcautionmessagemaycomeon. Whenthisoccurs, selecting the APU PWR/FUEL switchlight to on then off will usually clear the message. If the message clears, there is no operational restrictions and the anomaly shouldbe disregarded.
B. Stopping
To shutdown theAPU, the crew deselectstheSTART/STOP switchlight ontheAPU panel. TheAPUwill automaticallyshedits loadingand shutdown. The PWR/FUEL switchis deselectedto close thefuel shutoff valve andto remove primary electrical power totheECU.
Inthe eventof anemergency, theflight crewcan press theAPUFIREPUSH switchlight ontheglareshield. On theground,theAPU can be shutdown bypushing anAPU emergency stopbuttonlocatedin theaftequipment compartment orbyselectingthe APUshut-
off(cover-
guarded) switch ontheexternal services panelontheRHforward fuselage. Either selection sends asignaltotheECUto carryout animmediate shutdown.
NOTE

Ifoverspeed orovertemperature occurs duringflight, donot restarttheAPU.

 

Flight Crew Operating Manual  MASTER 
CSP A-
013 


 AUXILIARY POWER UNIT  Vol. 1  04-
40-

Control  REV 56, Jan 31/03 

PWR FUEL Switch/Light
Whenpressedin, crossflow/APUpumpis energized,APUINBITE,APUgauges energized, door scheduledto openandAPUfuel shut-
off valve opens.

PUMPFAILlight comes on to indicate that
crossflow/APUpumphas failed.


SOV FAILlight comes on to indicate that the APUfuelfeedSOV has failed.


APU Control Panel
Overhead Panel

 
 