APU SHUT- APUEMERSTOP Switch
Whenpressedin, starter motor is energizedandSTART light (amber) comes on. At 50%rpm, START light goes out.
FCU shut-
Vol. 1 REV56,Jan 31/03 or Flight Crew Operating Manual
Control REV 56, Jan 31/03 TheAPUgauges come onwhenthe electronic controlunit is powered (APUPWRFUEL switch/light pressedin).
TheAPUgauges go off whenthe electronic controlunit is not powered(APUPWR FUELswitch/light pressedout). APU Door and Run Indication <MST> Flight Crew Operating Manual MASTER
APU rpm.APU shuts downautomatically. APU OIL PRESS APUhas low oilpressure.APU shuts down automatically. (On groundonly). APU OIL TEMP APUhas highoiltemperature (325 C).APU shuts downautomatically. (On groundonly). APU FAULT Loss ofAPU control circuits (microprocessor, thermocouple or speed signal).APU shuts down automatically. APU SOV FAIL APUFuelFeedSOV not in aconfirmedposition (either open or closed). APU SOV OPEN APUFuelFeedSOV is open10 seconds after an APUfire condition.APUFUELSOV light, onAPU panel, comes on(amber). APU LCV FAIL Loadcontrol valve has failed(either open or closed). APU BLEED ON Loadcontrol valve is openandbarometric altitude is greater than15,000feet. X- |