External AC Power Features

Displayedwhen externalAC voltageis more than10 volts andfrequency is more than50Hz.
EICAS DIGITAL READOUT  GREEN  AMBER  WHITE  HALF INTENSITY MAGENTA  AMBER DASHES 
XX KVA  Loaded  Overload  Not loaded  Insufficient data  Invalid data 
XXX V  Between 106 and 124 volts  _  Less than 106 volts or more than 124 volts  _  Invalid data 
XXX HZ  Between 370 and 430 Hz  _  Less than 370 Hz or more than 430 Hz  _  Invalid data 

EICAS OUTLINE  GREEN  WHITE  HALF INTENSITY MAGENTA 

 ExternalAC available or in use  ExternalAC not available and not in use  Invalid data 

AC Electrical System Synoptic Page
Figure 07---20---3 Sheet 3


Flight Crew Operating Manual  MASTER 
CSP A-
013 


 ELECTRICAL AC Electrical System  Vol. 1  07-
20-

REV 56, Jan 31/03 

<0039> <0006>

IDG 1 or 2 caution (amber)
Indicates that IDG has low oilpressure or highoiltemperature.
GEN 1 or 2 OFF caution (amber)
Indicates that generator is off. (Indications are inhibitedduring start)
GEN 1 or 2 OVLD caution (amber)
Indicates that generator controlunit has detected aloadof greater than40kVA.
APU GEN OFF caution (amber)
Indicates thatAPUgenerator is off and APUis ready to load.
APU GEN OVLD caution (amber)
Indicates that generator controlunit has detected aloadof greater than40kVA.

IDG 1 or 2 DISC status (white)

<0039>
Indicates that IDG has beendisconnected,
either automatically or manually.


<0039>

Status Page
AC Electrical System EICAS Indication (Generators) <MST Figure 07---20---4

Flight Crew Operating Manual  MASTER 
CSP A-
013 


 ELECTRICAL  Vol. 1  07-
20-

AC Electrical System  REV 56, Jan 31/03 

<0039> <0006>


AC Electrical System EICAS Indications (Busses) <MST>
Figure 07---20---5


Flight Crew Operating Manual  MASTER 
CSP A-
013 


 ELECTRICAL AC Electrical System  Vol. 1  07-
20-
10 
REV 56, Jan 31/03 


voltagelevel.
TRU Load Readouts
Displays, inincrements of 1 amp, theload the rectifier.
AC BUS to TRU Flow Lines

Green -
Respective ACbus is powering TRU.
TRU Output Flow Lines

Green -
Respective TRUis on-
lineand output is 18VDC or greater.
EICAS DIGITAL READOUT  GREEN  WHITE  AMBER DASHES 
xx V  Between 22 and 29 VDC  Less than 22 VDC or more than 29 VDC  Invalid data 
 