Triple chime  Warning tone that precedes an aircraft system voice advisory  Chapters 2 through 20 
C-chord  Altitude alert  Chapter 12, Flight Instruments 
Single chime  Caution tone that precedes an aircraft systemvoice advisory  Chapters 2 through 20 

Flight Crew Operating Manual  MASTER 
CSP A-
013 

 

AURAL/VISUAL INDICATING AND
Vol. 1
02-
20-
8

RECORDING
REV56,Jan 31/03
Engine Indication and Crew Alerting System
<0019>
Audio Warning Panel Audio Warning Panel
Copilot’s Side Console Copilot’s Side Console

DCU 1, DCU 2, and DCU 3 (Guarded)<0019>
Miscellaneous Test Panel Center Pedestal  Aural Warning Test Switch (alternate action) 1 -
Tests all aural alerts within data concentrator unit 1. OFF -
Disable aural alert test.  NOTE To test DCU 3: -
Disable DCU 1. -
Settestswitch <0019> 
2 -
Tests all aural alerts within  to DCU 1. 
data concentrator unit 2. 
DCU 1, 2, or 3 INOP status (white) <0019> 
DCU 1 or 2 INOP status (white)Indicates internal fault or crosstalk fault 
in respective data concentrator unit. 

<0019>
<0039>
<0039>
DCU 1, 2, or 3 AURAL INOP status (white) <0019>
DCU 1 or 2 AURAL INOP status (white)
Indicates internal auralfault in respective data concentrator unit or indicates respective DCUauraloutput has beendisabled.

Status Page
DCU Controls and Indications <MST> Figure 02---20---6

Flight Crew Operating Manual
MASTER


CSP A-
013

 AURAL/VISUAL INDICATING AND RECORDING  Vol. 1  02-
20-

Engine Indication and Crew Alerting System  REV 56, Jan 31/03 

C. Master Warning / Master Caution Annunciator Lights
(1) MasterWarningAnnunciatorLights
The red MASTER WARNING push-
button annunciator(PBA) lights are installed on the left and right glareshield panels. Both lights will come on flashing when any warning occurs. Pushing either MASTER WARNING PBA will extinguishes both MASTER WARNING lights for the duration of that warning and resets the lights for future warnings. The warning message on the EICAS primary page will remain on as long as the warning exists.
Pushing the MASTER WARNING PBA also silences the aural warnings except for the following cases:
W Stallwarbler W Stabilizertrimclacker
W GPWS/TCAS(voices andaural) W APDisconnect cavalry charge
W Overspeed clacker W Configuration warnings
W Flapclacker W GearHorn
(2) MasterCaution AnnunciatorLights
The amber MASTER CAUTION push-
button annunciator(PBA) lights are installed on the left and right glareshield panels. Both lights will come on flashing when any caution occurs. Pushing either MASTER CAUTION PBA will extinguishes both MASTER CAUTION lights for the duration of that caution and resets the lights for future cautions.
 