is armedfor manual crossflow,
automatic crossflowis disabled.
MANUALlight goes on.

 


Pressedout -
Crossflow/APUpump
is disarmedfor manual crossflow,
automatic crossflowis enabled.
MANUALlight goes out.

 

L/R XFLOW switch/lights (With AUTO OVERRIDE switch/light pressed in, manual mode.)

Pressedin -
Respective crossflow SOV
opens and crossflow/APUpumpgoes on,
ONlight comes on.
Pressed out -
Respective crossflow SOV
closes andcrossflow/APUpumpgoes off,
ONlight goes out.

(With AUTO OVERRIDE switch/light pressed out, automatic mode.)


ONlight comes on to indicate that the
respective SOV is openandthe
crossflow/APUpumpis on.

 


FAILlight comes on to indicate that
the respective crossflowSOV is not
inthe commandedposition or the
crossflow/APUpumpfails to go
onwiththeleft or right crossflowSOV
selectedopeneither manually
or automatically.

 

Fuel Control Panel ---General
Figure 13---30---2


Flight Crew Operating Manual  MASTER 
CSP A-
013 


 FUEL SYSTEM  Vol. 1  13-
30-

Fuel Management  REV 56, Jan 31/03 

XFLOW/APU PUMP caution (amber)
Comes ontoindicate that the crossflow/APU pumphas failed.
L, RMAINEJECTOR
caution (amber)
Comes ontoindicate lowfuelpressure at respective mainejector with respective engine running.
L, R AUTO XFLOW ON status (white)
Comes ontoindicate
MAN XFLOW status (white)
has been selected.
L, R XFLOW ON status (white)
that the respective crossflow SOVis manually selected open.
status (white)
that the gravity crossflow SOVhas failed.