The systeminteractswiththe cargo baysmoke detectors andfire extinguishingsystem (See Chapter10,Fire Protection). When smoke is detected,the shut-off valves automatically close to isolatethe cargo compartment. <0043><0059>
The systeminteractswiththe cargo baysmoke detectors andfire extinguishingsystem (See Chapter10,Fire Protection). When smoke is detected,theheaterpoweris removedandthe shut-off valves automatically close to isolatethe cargo compartment. <0013><0034>
NOTE
For ground operations with the cargo compartment door open, the CARGO switch may be set to COND AIR. For ambient temperatures above 30bC(86bF), thismayresultinacargooverheat cautionmessage. The cargo switch must be reset to the FAN position afterthe cargo doorhasbeen closed. <0013><0034>
Flight Crew Operating Manual  MASTER 
CSP A-
013 


 ENVIRONMENTAL CONTROL SYSTEM Aft Cargo Bay Ventilation System  Vol. 1  08-
40-

REV 56, Jan 31/03 


DISTRIBUTION CONDITIONED-
AIR OVERHEAT COMPARTMENTMANIFOLD SHUT-
OFFVALVE SWITCH SUPPLY
Cargo Compartment Air System with Air Conditioning ---Schematic <0013><0034>
Figure 08---40---1

Flight Crew Operating Manual  MASTER 
CSP A-
013 


 ENVIRONMENTAL CONTROL SYSTEM  Vol. 1  08-
40-

Aft Cargo Bay Ventilation System  REV 56, Jan 31/03 


CARGO COMPARTMENT SUPPLY
Cargo Compartment VentilationSystem ---Schematic <0043><0059> Figure 08---40---2
Flight Crew Operating Manual  MASTER 
CSP A-
013 

Vol. 1
08-
40-
4
ENVIRONMENTAL CONTROL SYSTEM
REV56,Jan 31/03
Aft Cargo Bay Ventilation System
BAGG COMPT CONT DCBUS 1
BAGG COMPT FAN ACBUS1
BAGG COMPT SOV DCESS
Air-
Conditioning Panel Overhead Panel
<0013> <0043>
<0034> <0053>
<0074>

<0059>
CARGO FAN FAIL status (white)
Comes on to indicate lowair flow at cargo
bay recirculationfan.

CARGO SOV FAIL status (white)
Comes on to indicate that air supply shut-
off
valve has failed(either open or closed).

<0039> <0006>
Primary Page
Cargo Bay Air Conditioning Switch <0013><0034><0074> Usedto select to system mode.
CONDAIR -
Temperature controlled airflow provided to cargo bay area. FAN -
Recirculated cabin exhaust air providedto cargo bay area. OFF -
Shuts offairflowto the cargo bay area.
<0043>
<0053>
Cargo Bay Mode Switch<0059>

Usedto select to system mode. FAN -
Recirculated cabin exhaust air providedto cargo bay area. OFF -
Shuts offairflowto the cargo bay area.
 