Cargo Compartment Air/ventilation System <MST>
Figure 08---40---3
Flight Crew Operating Manual
MASTER
CSP A-
013
ENVIRONMENTAL CONTROL SYSTEM Vol. 1 08-
40-
5
Aft Cargo Bay Ventilation System REV 56, Jan 31/03
A. System Circuit Breakers
SYSTEM SUB-
SYSTEM CB NAME BUS BAR CB PANEL CB LOCATION NOTES
Controller BAGG COMPT CONT DC BUS 1 1 L3
Cargo Bay Conditioned Ai SyAir
Sys
t
e
m
Heater BAGG COMPT HEATER AC BUS 1 1 B8 <0013> <0034> <0074>
Fan BAGG COMPT FAN AC BUS 1 1 D5
Shutoff Valve BAGG COMPT SOV DC ESS 4 A12
Flight Crew Operating Manual MASTER
CSP A-
013
ENVIRONMENTAL CONTROL SYSTEM Aft Cargo Bay Ventilation System Vol. 1 08-
40-
6
REV 56, Jan 31/03
THISPAGEINTENTIONALLYLEFTBLANK
Flight Crew Operating Manual MASTER
CSP A-
013
ENVIRONMENTAL CONTROL SYSTEM Vol. 1 08-
50-
1
Lavatory and Galley Ventilation System REV 56, Jan 31/03
Effectivity:
W Aircraft7002,7050and subsequent.
W Aircraft7003to7010,7015,7016,7019to7021,7023 to7025, 7032,7033, 7036,7039,
7040incorporatingSB601R-
25-
012.
1. GALLEY HEATING SYSTEM
The galleyis heatedwithtwo 500 wattheaters to provide supplementaryheatto thegalleyand service doorarea. Oneheater uses theair fromtheright exhaust riserductandthe second heaterwarms conditionedair from the rightgaspersupplyduct. The heaters are controlledby switchlights on theFlightAttendantspanel. There is no EICASdisplayfor thegalleyheating system.
Eachheaterincorporates aninternal overtemperature switchthat removes power totheheater whentheheateroutlettemperature becomes excessive. Theheateralso incorporates an internal, overheatprotection switch whichdisables theheater whentheinternaltemperature exceeds apresetlimit. Heater#1has afan which can beusedin conjunction with orseparate from theheaters.
System testis accomplished usingtheSYSTEM1&2TEST switchlight ontheFlight
Attendantspanel asfollows:
LatchtheFANandHTR1and2 switchlightsand checkthat:
W The FAN and HRT1 and 2 lights illuminate green.
Press theTEST switchlightandhold; checkthat:
W The FANFAIL and HTR1 and2INOPlights illuminate (amber), and
W The FANandHRT1and2green lightsgo out.
Release theTEST switchlightand checkthat:
W The HTR2INOPlightgoesout,and
W The FANFAILandHTR1INOPlights remain ON.